Finished projects of one-storey houses - Shidny (95 м²)
The project of a comfortable one-storey house with two bedrooms, a kitchen connected to a living room and a terrace.:
- Total area:95 м²
- House dimensions:11.2 м х 11.0 м
CONSTRUCTION:
- Foundations:Tape monolith reinforced concrete
- Exterior Walls:Aerated concrete block 400 mm
- Overlaps:Reinforced concrete panels
- Roof:Pitched
- Roofing:Bitumen tile
Project price:
609 €
| Parameter | data |
|---|---|
| Foundations | Tape monolith reinforced concrete |
| Walls | Aerated concrete block 400 mm |
| Roofing | Bitumen tile |
| Number of floors | 1 |
| First floor floor | On the ground |
| Ground floor height | 2.87 м |
| Overlap of the first floor | Reinforced concrete panels |

The foundation is tape monolithic reinforced concrete. One of the foundation options is the device of a compacted sand cushion, which was laid to replace the selected soft soils. A sand cushion should be made of medium-grained sand. The sand cushion should be laid in 20 cm thick layers, compacted with heavy rollers and each layer moistened. This type of foundations was adopted based on the results of geological surveys and high groundwater levels.
The floor of the house is on a concrete base with a thickness of 100 mm, which is reinforced with a mesh of 150 x 150 mm.
The horizontal waterproofing under the walls and floor shall be made of a fused bitumen-polymer membrane. Insulate the floor of the house with 150 mm expanded polystyrene. On top of the expanded polystyrene, arrange a 50mm thick cement-sand screed reinforced with a mesh. External walls and internal load-bearing wall made of 400 mm thick aerated concrete blocks. Partitions are made of aerated concrete blocks 100 mm thick. The slabs are standard reinforced concrete slabs. Ceilings must be insulated with foam or basalt wool 350 mm thick. Roofing with bituminous or metal shingles.
The horizontal waterproofing under the walls and floor shall be made of a fused bitumen-polymer membrane. Insulate the floor of the house with 150 mm expanded polystyrene. On top of the expanded polystyrene, arrange a 50mm thick cement-sand screed reinforced with a mesh. External walls and internal load-bearing wall made of 400 mm thick aerated concrete blocks. Partitions are made of aerated concrete blocks 100 mm thick. The slabs are standard reinforced concrete slabs. Ceilings must be insulated with foam or basalt wool 350 mm thick. Roofing with bituminous or metal shingles.
Heating - electric boiler or heat pump. In the case of using a gas or solid fuel boiler in the boiler room, it is necessary to make a window and provide for a chimney and ventilation pipe. Exterior wall decoration with decorative plaster.
Another house project with an area of 95 m2 is "Camellia 3". This project can be viewed here
In addition, we can develop an individual design project for facades and interiors.
If necessary, individual projects of engineering sections can be developed: heating and sewerage, ventilation and power supply projects.
The presence of engineering systems projects greatly simplifies construction and reduces the number of alterations.